    When the generator is in operation, it is not advisable to continue to discharge water when the temperature is high. The engine should be idling after the water is discharged in the cold winter. In the cold winter, the engine should be started and idling for a few minutes after the cooling water in the backup generator. The temperature can dry the residual moisture in the water pump, so that there is no water in the engine, and prevent the water pump from freezing and tearing the water seal and causing water leakage.
 
1. Replenish soft water in time
After filling the water tank with antifreeze, if the liquid level of the water tank is found to be lowered, fill it with clean soft water (distilled water is better) under the premise of no leakage, because the generally used glycol type antifreeze has a high boiling point and evaporates It is the moisture in the antifreeze, you don't need to add the antifreeze but add soft water. Be careful not to add hard water that has not been softened.
2. Discharge the antifreeze in time to reduce corrosion
Whether it is ordinary antifreeze or other antifreeze, it should be released at a time when the temperature becomes higher, to prevent the corrosion of the mechanical parts. Because the preservative added to the antifreeze will decrease or become invalid with the extension of use time, the antifreeze should be released in time according to the temperature, and the cooling pipeline should be cleaned after the antifreeze is released.
3. change the water and clean the pipeline
It is not recommended to change the cooling water, because the cooling water of the standby generator has been used for some time, and the minerals have been precipitated unless the water is very dirty and may block the pipeline and the radiator, even if the replaced cooling water has been softened. But it also contains minerals, which will deposit and form scale. The more the water is replaced, the more minerals will be precipitated and the thicker the scale will be. So, the cooling water should be replaced according to the actual situation. The cooling pipeline should be cleaned during replacement. The cleaning fluid can be prepared with caustic soda, kerosene, and water. At the same time, maintain the drain switches. Before the winter, replace the damaged switches in time. Bolts, sticks, rags, etc. cannot be used as replacements.
4. Open the water tank cover when discharging water
If the water tank cover is not opened when the water is discharged, part of the cooling water can flow out, but as the amount of water in the radiator decreases, the water tank is closed and a vacuum degree will be generated, which will slow down or stop the water flow. In winter, the water will be frozen due to impure water discharge. Broken parts.

Weifang, shandong province, China 中国 山东。潍坊

     Sales hotline: +8615905360672
         WhatsApp: +8615905360672
   Email address: huaquan@huaquanpower.com
  Official website: https://www.huaquanpower.com
Production Base: No. 11666 Guting Street, Economic Development Zone,
                            Weifang City, Shandong Province
Company Name: SHANDONG HUAQUAN POWER CO.,LTD
销售热线:+8615905360672
微信客服:+8615905360672
邮箱地址:huaquan@huaquanpower.com
官方网站:https://www.huaquanpower.com
生产基地:山东省潍坊市经济开发区古亭街11666号
公司名称:山东华全动力股份有限公司

Shandong Huaquan Power Co., Ltd.

Permanent copyright